Document revision date: 30 March 2001
|
|
|
|
OpenVMS System Messages: Companion Guide for Help
Message Users
Cables have gone from CROSSED to UNCROSSED - REMOTE PORT 'xxx'
Facility: Cluster Port Driver
Explanation: A former crossed cable condition has been
corrected.
User Action: None.
Cables have gone from UNCROSSED to CROSSED - REMOTE PORT 'xxx'
Facility: Cluster Port Driver
Explanation: A self-test loopback packet has detected
a crossed cables condition or other software failure.
User Action: Check for crossed cable pairs. If none
are found, contact a Compaq support representative.
CANTASSIGN, Error assigning a channel to the PK device.
Facility: STACONFIG, Standalone Configure Process
Explanation: The $ASSIGN system service did not
complete successfully.
User Action: Contact a Compaq support representative.
CANTEXPREG, cannot expand virtual address space
Facility: BACKUP, Backup Utility
Explanation: Standalone BACKUP attempted
unsuccessfully to expand its virtual address space.
User Action: If this error can be reliably reproduced,
note the circumstances under which it occurs, including the BACKUP
command used. Contact a Compaq support representative.
CANTLOCK, cannot lock pages into memory; reboot if the system disk goes
off line
Facility: BACKUP, Backup Utility
Explanation: Standalone BACKUP cannot lock the
required pages into the working set.
User Action: Normally, no action is necessary.
However, if the system disk goes off line, it will be necessary to
reboot the system. The operation of standalone BACKUP is likely to be
very slow because there is insufficient memory to lock down a small
portion of the working set.
CAPTIVE, qualifier not allowed in captive accounts
Facility: LOGIN, Login Procedure
Explanation: An attempt was made to use qualifiers
(for example, /CLI or /DISK) on a captive account that is logging in.
If the account logging in is a captive account, no qualifiers may be
used.
User Action: Retry without specifying qualifiers.
CBSNOTSUPTD, Attention - Phase I Shadowing is not supported as of
OpenVMS VAX V6.1
Facility: MOUNT, Mount Utility
Facility: SYSBOOT, System Bootstrap Facility
Explanation: You specified a phase I volume shadowing
virtual unit (DUSnn) in a command. OpenVMS VAX no longer
supports phase I volume shadowing.
User Action: Reissue the command, using a phase II
volume shadowing virtual unit name (DSAnn) consistent with
phase II (host-based) volume shadowing.
CDROM_HS, 'volnam':'volsetnam' ('volnum' of 'volsetsiz'), 'text'
Facility: MOUNT, Mount Utility
Explanation: This message identifies a High Sierra
formatted CD-ROM volume.
User Action: None.
CDROM_ISO, 'volnam':'volsetnam' ('volnum' of 'volsetsiz'), 'text'
Facility: MOUNT, Mount Utility
Explanation: This message identifies an ISO 9660
formatted CD-ROM volume.
User Action: None.
CEBREFNEG, negative reference count on shared memory CEB
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
CHMONIS, change mode instruction while on interrupt stack
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
CHMVEC, CHM vector bits <1:0> not 0
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
CI port timeout
Facility: Cluster Port Driver
Explanation: The port driver attempts to reinitialize
the port; after 50 attempts, it marks the device off line.
User Action: Contact a Compaq support representative to check the port
hardware, the CI cable, and the node number configuration.
CI port Virtual Circuit SETCKT OPEN timeout: Restart Port
Facility: Cluster Port Driver
Explanation: When the CI port found a new, remote CI
node, the CI port did not complete the processing of a
"virtual-circuit-open" command within the permitted virtual-circuit
timeout period. The local CI port is either hung, offline, or saturated
with activity, or the CI response queue processing CPU remained at or
above IPL-8 for an extended period.
User Action: The port restarts automatically. If this
error recurs, it indicates problems with port load balancing, system
tuning, or faulty hardware or firmware on the CI port.
CIASHUTDOWN, breakin detection and evasion processing is shutting down
Facility: SECSRV, Security Server
Explanation: The break-in detection and evasion
processing component of the security server is shutting down upon
request.
User Action: None required. If you wish to restart the
security server, issue the DCL command SET SERVER SECURITY/START.
CIASTARTINGUP, breakin detection and evasion processing now starting up
Facility: SECSRV, Security Server
Explanation: The break-in detection and evasion
processing component of the security server is starting up, as
requested.
User Action: None.
CIATERMINATED, an error caused breakin detection and evasion processing
to terminate
Facility: SECSRV, Security Server
Explanation: An error occurred in the break-in
detection and evasion processing component of the security server.
User Action: Contact a Compaq support representative.
CIPORT, fatal error detected by CI port driver (PADRIVER)
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
CLIFAIL, error activating command interpreter 'CLI-name'
Facility: LOGIN, Login Procedure
Explanation: An error occurred while attempting to
invoke the specified command interpreter for your process.
User Action: Ensure that the command interpreter image
exists and that the image file has read access.
CLIPROT, error protecting command interpreter pages
Facility: LOGIN, Login Procedure
Explanation: An error occurred while attempting to
protect the command interpreter pages.
User Action: Take action based on the accompanying message.
CLISYMTBL, error creating space for command interpreter symbol table
Facility: LOGIN, Login Procedure
Explanation: There is not enough virtual address space
available to create the command interpreter symbol table.
User Action: On VAX systems, check that the system is
set up with the value of VIRTUALPAGECNT large enough to allow the CLI
to be mapped.
CLITBLFAIL, error activating command interpreter tables 'table-name'
Facility: LOGIN, Login Procedure
Explanation: LOGIN cannot access the specified command
language interpreter tables.
User Action: Determine whether the specified tables
exist and, if they do, make sure they are not protected against system
read access.
CLITBLPROT, error protecting command interpreter tables pages
Facility: LOGIN, Login Procedure
Explanation: An error occurred when the system tried
to write-protect the command interpreter table pages.
User Action: Try again. If the error recurs, report it
to your system manager.
CLOSEIN, error closing 'file-name' as input
Facility: BACKUP, Backup Utility
Explanation: The Backup utility cannot close the
specified input file for the reason stated in an accompanying RMS file
system message.
User Action: Correct the error and retry the backup
operation.
CLOSEOUT, error closing 'file-name' as output
Facility: BACKUP, Backup Utility
Explanation: The Backup utility cannot close the
specified output file for the reason stated in an accompanying message.
User Action: Correct the error and retry the backup
operation.
CLUEXIT, node voluntarily exiting VMScluster
Facility: BUGCHECK, System Bugcheck
Explanation: To avoid partitioning of the cluster,
this system exited the cluster by crashing. After all physical memory
is written to a system dump file, the system automatically reboots if
the BUGREBOOT system parameter is set to 1.
Generally, this condition arises when the intracluster communications
of one or more systems is delayed in some way. This condition can also
occur if one system is incorrectly booted on a common system disk using
another system's duplicate SYSROOT identifier, or if a copy of an
existing system disk is booted on another machine. If the condition
persists, this system may have been incorrectly physically configured
as part of two distinct OpenVMS Cluster systems.
User Action: Ensure that the cluster is properly
configured or that the proper root and disk are specified in the boot
command.
CLUSTER, unsuitable cluster factor for 'device-name'
Facility: BACKUP, Backup Utility
Explanation: During an attempt to initialize an output
volume, the Backup utility found that the cluster factor was too large
or too small for the specified device.
User Action: If the input is a save set, use the
BACKUP/LIST command to determine the volume initialization parameters
of the input volumes. Refer to the description of the DCL command
INITIALIZE, determine a suitable cluster factor, and initialize the
output volumes using the INITIALIZE command. Then, reenter the command
specifying the /NOINITIALIZE qualifier.
CMDERROR, error reported by command executor
Facility: LAT, LAT Facility
Explanation: The command executor module for LATCP
cannot execute the command.
User Action: Take action based on the accompanying message.
CMDINPUT, error reading command input
Facility: LOGIN, Login Procedure
Explanation: An error occurred during the entry of the
command; for example, the timeout period following the prompt for user
name or password expired before a response was entered.
User Action: Repeat the login procedure.
CMDOBS, command obsolete - ignored
Facility: LAT, LAT Facility
Explanation: The specified LATCP command is obsolete;
the command is ignored.
User Action: Discontinue use of this command.
CMDOBS, MSCP server must be loaded by setting SYSBOOT parameter
MSCP_LOAD
Facility: SYSGEN, System Generation Utility
Explanation: The MSCP command in SYSGEN is now
obsolete.
User Action: To load the MSCP server, set the SYSGEN
parameter MSCP_LOAD. This will load the MSCP server during SYSBOOT.
Setting the SYSGEN parameter to load the MSCP server during SYSBOOT
will result in a warning when you enter the MSCP command in SYSGEN. If
this error is printed as the result of a startup command procedure,
changing the parameter to load the server earlier will enable the old
command procedure to complete successfully with only a warning message.
CMPOUTF11, /COMPARE requires save set as first input
Facility: BACKUP, Backup Utility
Explanation: In a compare operation between a save set
and a disk volume, you must specify the save set as the first input and
the disk volume as the second input.
User Action: Correct and reenter the command.
CNXMGRERR, error detected by VMScluster Connection Manager
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
COMMAND_REPEAT, duplicate 'keyword' command for device 'device-name' is
ignored, at line 'line-number'.
Facility: READ_CONFIG, File-Based Autoconfiguration
Explanation: A command was repeated within a
description. Only the initial occurrence within the description will be
used; subsequent occurrences will be ignored.
User Action: Check your configuration files for
invalid records.
COMPARED, compared 'file-spec'
Facility: BACKUP, Backup Utility
Explanation: The Backup utility successfully completed
a compare operation. This message is displayed only when the /LOG
command qualifier is used.
User Action: None.
CONFIGURED, Configured device 'device'
Facility: IOGEN
Explanation: The specified device has been configured.
User Action: None.
CONFQUAL, conflicting qualifiers, request aborted
Facility: SYSGEN, System Generation Utility
Explanation: You entered the SYSGEN command
AUTOCONFIGURE with both the /EXCLUDE and /SELECT qualifiers.
User Action: Reenter the command, using only one of
these qualifiers.
CONNERR, error connecting to 'terminal-name'
Facility: LOGIN, Login Procedure
Explanation: An error occurred when the system
attempted to reconnect to the specified disconnected terminal.
User Action: Try again. If the error recurs, report it
to your system manager.
CONSTERROR, security server experienced a CONSTRAINT_ERROR exception
Facility: SECSRV, Security Server
Explanation: An error occurred in the security server.
User Action: Contact a Compaq support representative.
CONTINUE, unable to continue processing 'file-spec'
Facility: BACKUP, Backup Utility
Explanation: The specified file, which is being
processed at a change of save-set volumes, is no longer accessible. The
Backup utility terminates processing of the file. If other file
activity is occurring on the volume, the error is probably caused
because another user deleted the file during the backup process.
User Action: None; however, note that the file is
incompletely processed.
CONTINUED, 'save-set-spec' contains a continued file - cannot append
Facility: BACKUP, Backup Utility
Explanation: In a save operation with the /NOREWIND
qualifier, the specified volume contained a multivolume file that is
continued on another volume; therefore, a file cannot be appended to
the volume.
User Action: Retry the operation using the /REWIND
qualifier to force the Backup utility to initialize the output volume
or use another volume.
CONTRACT, contract virtual address space error
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
COPIED, copied 'file-spec'
Facility: BACKUP, Backup Utility
Explanation: The Backup utility successfully completed
a save operation. This message is displayed only if the /LOG qualifier
is specified.
User Action: None.
CORRUPTEMB, EMB packet header has been corrupted
Facility: BUGCHECK, System Bugcheck
Explanation: The system detected corruption of the
system error log buffers. The system allocates space for error log
entries from a set of common buffers. System software that makes use of
the error logging routines typically writes into these entries. This
message occurs when an attempt to write into an error log entry has
overwritten other parts of the system error log buffers. The most
common cause of this error is a coding error within a device driver.
User Action: Use the BACKUP command with the
/IGNORE=NOBACKUP qualifier to make a backup save set of the system dump
file generated by this error. Contact a Compaq support representative and describe the
conditions leading to the error.
COULDNTRESTART, security server cannot restart because of the following
error:
Facility: SECSRV, Security Server
Explanation: The security server was directed to
restart itself but the error reported in the accompanying message
prevented this action.
User Action: Take action based on the accompanying
message.
COULDNTSTART, security server cannot start functioning properly
Facility: SECSRV, Security Server
Explanation: The security server failed to start for
the reason described in an accompanying message.
User Action: Take action based on the accompanying
message.
CPU ucode not at required rev level for port activity
Facility: Cluster Port Driver
Explanation: The port driver will not attempt to start
the port.
User Action: On a VAX-11/750 system, make sure that
the console TU58 is present and up-to-date. Otherwise, contact
a Compaq support representative to check the port hardware.
CPUCEASED, CPU ceased execution
Facility: BUGCHECK, System Bugcheck
Explanation: The OpenVMS software detected an
irrecoverable, inconsistent condition. After all physical memory is
written to a system dump file, the system automatically reboots if the
BUGREBOOT system parameter is set to 1.
User Action: Use the BACKUP command with the /IGNORE=NOBACKUP qualifier to make a backup save set of the system dump file and the error log file active at the time of the error. Contact a Compaq support representative and describe the conditions leading to the error.
CPUNOTSUPP,
The processor device on SCSI bus 'device-name',
ID 'slot-number',
is not supported in a multihost SCSI VMScluster environment. The
processor vendor ID is 'vendor-id' and the product ID is 'product-id'.
Facility: STACONFIG, Standalone Configure Process
Explanation: An unsupported processor device was
discovered on the bus.
User Action: If you are operating in a multihost SCSI
OpenVMS Cluster environment, remove the specified unsupported device.
If you are not operating in a multihost SCSI OpenVMS Cluster
environment, specify the processor device using the SYSGEN parameter
SCSICLUSTER_Pn=abcd, where:
n = 1, 2, 3, or 4
ab = The first two letters of the processor's vendor ID
cd = The first two letters of the processor's product ID
CREATED, created 'file-name'
Facility: BACKUP, Backup Utility
Explanation: This informational message appears for
every file that is created when the /LOG qualifier is used in the
BACKUP command for a restore or copy operation.
User Action: None.
CREDIR, created directory 'directory-name'
Facility: BACKUP, Backup Utility
Explanation: The Backup utility successfully created
the directory 'directory'. This message is displayed only if the /LOG
qualifier is specified.
User Action: None.
CREDIRERR, error creating directory 'directory-name'
Facility: BACKUP, Backup Utility
Explanation: The Backup utility encountered an error
during an attempt to create the specified directory.
User Action: Take action based on the accompanying message.
CRELNM_FAILED, failed to create logical name 'name' in table
'table-name'
Facility: MOUNT, Mount Utility
Explanation: The mount operation completed
successfully, but the Mount utility could not create the requested
logical name. An accompanying message explains the reason for the
failure.
User Action: None required. If you wish, you can
manually assign the logical name after the reason for the failure has
been resolved.
CREPARFIL, unable to create parameter file
Facility: SYSGEN, System Generation Utility
Explanation: An error occurred during a write
operation.
User Action: Reenter the command so that you can write
to the file.
CREPRCFL, Could not create new process
Facility: BACKUP, Backup Utility
Explanation: Standalone BACKUP cannot create the
process necessary to perform the requested additional backup operation.
User Action: Reboot the system with standalone BACKUP
in order to perform further backup operations.